คำอธิบาย
RG-CS83-48GT4XS-PD Ruijie
Specifications
Hardware Specifications
Hardware Specifications | RG-CS83-24GT4XS-PD | RG-CS83-48GT4XS-PD |
Interface Specifications | ||
Fixed ports | 24 x 10/100/1000 BASE-T ports
4 x 1G/10G SFP+ ports PoE standards: IEEE 802.3af and 802.3at |
48 x 10/100/1000 BASE-T ports
4 x 1G/10G SFP+ ports PoE standards: IEEE 802.3af and 802.3at |
Fans modules | 1 x fixed fan module | 1 x fixed fan module |
Power modules | 2 replaceable hot-swappable power supply slots | 2 replaceable hot-swappable power supply slots |
Fixed management ports | 1 x MGMT port, 1 x console port, and 1 x USB port | 1 x MGMT port, 1 x console port, and 1 x USB port |
System Specifications | ||
Packet forwarding rate | 96 Mpps | 132 Mpps |
Switching capacity | 128 Gbps | 176 Gbps |
MAC address table size | 32,000 | |
ARP table size | 4,000 | |
Number of IPv4 unicast routes | 8,000 | |
Number of IPv4 multicast routes | 2,500 | |
Number of IPv6 unicast routes | 4,000 | |
Number of IPv6 multicast routes | 1,200 | |
Number of ACEs | Ingress: 3,500
Egress:1,500 |
|
Number of VSU members | 4 | |
VLAN translation | 4,094 | |
Dimensions and Weight | ||
Dimensions (W x D x H) | 442 x 420 x 43.6 mm (17.40 x 16.54 x 1.72 in), 1 RU | |
Weight (empty chassis and fan modules) | 4.3 kg (9.48 lbs) | 4.6 kg (10.14 lbs) |
CPU and Storage | ||
CPU | Dual cores, with the clock speed of 1.2 GHz | |
Flash memory | 2 GB | |
BootROM | 16 MB | |
SDRAM | 1 GB | |
Data packet buffer | 3 MB | |
Power and Consumption | ||
Maximum power consumption | < 65 W (non-PoE)
< 810 W (PoE full load) |
< 75 W (non-PoE)
< 1570 W (PoE full load) |
Maximum output power | RG-PA600I-P-F: 600 W (PoE: 370 W)
RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000W 90 V AC to 176 V AC, 930 W (PoE: 740 W) |
|
Rated input voltage | RG-PA600I-P-F:
AC: 100 V AC to 240 V AC, 50/60 Hz HVDC: 240 V DC RG-PA1000I-P-F: AC: 100 V AC to 240 V AC, 50/60 Hz HVDC: 240 V DC |
|
Maximum input voltage | RG-PA600I-P-F:
AC: 90 V AC to 264 V AC, 47/63 Hz HVDC: 192 V DC to 288 V DC RG-PA1000I-P-F: AC: 90 V AC to 264 V AC, 47/63 Hz HVDC: 192 V DC to 288 V DC |
|
Environment and Reliability | ||
MTBF | ≥ 356,000 hours (dual power modules)
≥ 208,000 hours (single power module) |
≥ 315,000 hours (dual power modules)
≥ 193,000 hours (single power module) |
Primary Airflow | Left-to-right and front-to-right airflow | |
Operating temperature | 0°C to 45°C (32°F to 113°F) | |
Storage temperature | -40°C to +70°C (-40°F to +158°F) | |
Operating humidity | 10% to 90% RH (non-condensing) | |
Storage humidity | 5% to 95% RH (non-condensing) | |
Operating noise | 27°C: 51.6 dB
45°C: 57.4 dB |
27°C: 51.6 dB
45°C: 58.3 dB |
Interface surge protection | Power port: 6 kV/6 kV
Telecom port: 10 kV (MGMT port: 4 kV) |
Power port: 6 kV/6 kV
Telecom port: 10 kV (MGMT port: 4 kV) |
Software Specifications
RG-CS83-PD Series | |
Feature | Description |
Ethernet switching | Jumbo frame (maximum length: 9216 bytes) |
IEEE 802.1Q (4K VLANs) | |
Voice VLAN | |
Super VLAN and private VLAN | |
MAC VLAN, port-based VLAN, protocol-based VLAN, and IP-subnet based VLAN | |
GVRP | |
Basic QinQ
Selective QinQ |
|
STP, RSTP, and MSTP | |
ERPS (G.8032) | |
LLDP/LLDP-MED | |
LACP (IEEE 802.3ad) | |
IP service | ARP |
DHCP client, DHCP relay, and DHCP server | |
DHCP snooping | |
DNS | |
DHCPv6 client and DHCPv6 relay | |
DHCPv6 snooping | |
Neighbor Discovery (ND) and ND snooping | |
IP routing | Static routing |
RIP, RIPng | |
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 | |
BGP4 and BGP4+ | |
IPv4 and IPv6 VRF | |
IPv4 and IPv6 PBR | |
Multicast | IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2/v3 snooping | |
PIM-DM, PIM-SM, and PIM-SSM | |
MSDP | |
MLD v1/v2 | |
MLD snooping v1/v2 | |
PIM-SMv6, PIM-SSM v6 | |
ACL and QoS | Standard IP ACLs
Extended IP ACLs Extended MAC ACLs ACL80 IPv6 ACL |
ACL redirection | |
Port traffic identification | |
Port traffic rate limiting | |
802.1p/DSCP/ToS traffic classification
Eight priority queues per interface |
|
Traffic policing: CAR | |
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | |
Congestion avoidance: tail drop, RED, and WRED | |
Rate limiting in each queue | |
Security | Multiple AAA modes |
RADIUS and TACAS+ | |
Port-based and MAC-based 802.1x authentication | |
Web authentication | |
Allowlist | |
HTTPS | |
SSHv1, SSHv2 | |
Global IP-MAC binding | |
ICMP | |
Port isolation and port security | |
IP Source Guard | |
SAVI | |
Gateway ARP anti-spoofing | |
CPP(CPU Protection Policy) | |
NFPP( Network Foundation Protection Policy) | |
Strict and loose RPF
uRPF ignoring default routes |
|
Reliability | REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP | |
BFD | |
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) | |
Hot swapping of power modules and cables | |
3-level fan speed adjustment
Fan fault alarm |
|
Device virtualization | Virtual Switching Unit (VSU) |
NMS and maintenance | SPAN, RSPAN, and ERSPAN |
sFlow | |
NTP and SNTP | |
FTP and TFTP | |
SNMP v1/v2/v3 | |
RMON (1, 2, 3, 9) | |
NETCONF | |
CWMP (TR-069) standard protocol | |
gRPC | |
Cloud and SON | |
PoE | IEEE 802.3af and 802.3at
Uninterruptible power supply upon hot start Port priority |